An electronic device that converts single-mode optical interface to multimodes optical or vice versa. It can extend the distance of the optical signal due to the technical capacities of the single-mode optical fiber.
NAMEDITEM NAME
NOUN, WITH OR WITHOUT MODIFIERS, BY WHICH AN ITEM OF SUPPLY IS KNOWN.
Enter the item name code.
(NAMED68350*)
APQLJFREQUENCY BANDWIDTH
THE DIFFERENCES BETWEEN LIMITING FREQUENCIES OF A FREQUENCY BAND.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(APQLJEC2.0*;APQLJEC2.0$$JEC2.1*)
| Table 1 |
| Reply Code (AC32) | Reply |
| G | GIGAHERTZ |
| E | HERTZ |
| K | KILOHERTZ |
| M | MEGAHERTZ |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CYFJ*DOPTICAL FIBER TESTED TYPE
INDICATES THE TYPE OF OPTICAL FIBER TO BE TESTED.
Enter the applicable reply code from the table below
(CYFJDAAF*;CYFJDAAG$DAAG*;CYFJDAAG$$DAAG*)
| Table 1 |
| Reply Code (AK75) | Reply |
| AAF | MULTIMODE |
| AAG | SINGLE-MODE |
AJTUDOPTICAL FIBER TYPE
THE TYPE OF OPTICAL FIBER IN THE CONDUCTOR.
Enter the applicable reply code from the table below
(AJTUDAAF)
| Table 1 |
| Reply Code (AK75) | Reply |
| AAF | MULTIMODE |
| AAG | SINGLE-MODE |
CYFLJMAXIMUM DISTANCE IN METERS
THE MAXIMUM DISTANCE THAT CAN BE MEASURED WITH ACCURACY,EXPRESSED IN METERS.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CYFLJK2.0*)
| Table 1 |
| Reply Code (AA05) | Reply |
| K | KILOMETERS |
| M | METERS |
CYFKDOPTICAL PULSE WAVELENGTH IN NANOMETERS
THE PULSE WAVELENGTH USED FOR THE MEASUREMENT OF FAULTS,OPTICAL LOSSES,SPLICING POSITION AND LOSSES,EXPRESSED IN NANOMETERS.
Enter the applicable reply code from the table below
(CYFKDAP*;CYFKDHK$$DAW*)
| Table 1 |
| Reply Code (AP07) | Reply |
| AP | 1300 |
| HK | 1550 |
| HJ | 825 |
| AW | 850 |
BHTH*BATTENUATION IN DECIBELS
THE DECREASE IN STRENGTH OF AN ELECTRICAL IMPULSE,EXPRESSED IN DECIBELS.
Enter a reply with a minimum of one digit on either side of the decimal point.
(BHTHB2.0)
ABJH*JTEMP RATING
A VALUE WHICH EXPRESSES THE DEGREE OF HEAT OR COLD AS APPLIED TO THE OPERATION,OR LIMITATION OF OPERATION,OF AN ITEM.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit as in the first and second examples.For negative temperature values, precede the numeric portion of the reply with the letter “M” as in the third and fourth examples.If ISAC coding is authorized for this requirement and one or more of the temperature values in negative, enter the applicable ISAC from Table 1 below followed by the mode code and applicable Reply Code from Table 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.Also precede the numeric portion of the reply with the letter “M” as in the fifth and sixth examples.
(ABJHJF68.0*; ABJHJC0.0$$JC35.0*; ABJHJFCM15.0*; ABJHJFM40.0$$JF75.0*; ABJH1BJFM25.0*; ABJH1BJCM35.0$$JCM5.0*)
| Table 1 |
| Reply Code (AB36) | Reply |
| C | CELSIUS |
| F | FAHRENHEIT |
AEHX*JMAXIMUM POWER DISSIPATION RATING
THE MAXIMUM AMOUNT OF ELECTRICAL ENERGY THAT CAN BE EXPENDED BY AN ITEM.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AEHXJD2.0*)
| Table 1 |
| Reply Code (AC33) | Reply |
| D | DECIBELS |
| K | KILOVOLT-AMPERE |
| L | KILOWATTS |
| M | MILLIWATTS |
| E | VOLT-AMPERE |
| W | WATTS |
ACYN*JAC VOLTAGE RATING
THE VALUE,OR RANGE OF VALUES,OF ROOT MEAN SQUARE POTENTIAL FOR WHICH THE ITEM IS RATED.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ACYNJUA2.0*;ACYNJUA2.0$$JUA2.1*)
| Table 1 |
| Reply Code (AB63) | Reply |
| K | KILOVOLTS |
| M | MEGAVOLTS |
| U | MICROVOLTS |
| L | MILLIVOLTS |
| V | VOLTS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ACZB*JFREQUENCY RATING
THE NUMBER OF COMPLETE CYCLIC CHANGES,PER UNIT OF TIME,FOR WHICH AN ITEM IS RATED.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ACZBJMA2.0*;ACZBJMA2.0$$JMA2.1*)
| Table 1 |
| Reply Code (AC32) | Reply |
| G | GIGAHERTZ |
| E | HERTZ |
| K | KILOHERTZ |
| M | MEGAHERTZ |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
FAAZ*DPHASE
THE NUMBER OF ALTERNATING CURRENT PHASES.
Enter the applicable reply code from the table below
(FAAZDE*;FAAZDB$DC*)
| Table 1 |
| Reply Code (AD02) | Reply |
| A | SINGLE |
| E | SINGLE/THREE |
| C | THREE |
| B | TWO |
ACYR*JDC VOLTAGE RATING
THE VALUE,OR RANGE OF VALUES,OF DIRECT CURRENT POTENTIAL FOR WHICH THE ITEM IS RATED.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ACYRJVA2.0*;ACYRJVA2.0$$JVA2.1*)
| Table 1 |
| Reply Code (AB63) | Reply |
| K | KILOVOLTS |
| M | MEGAVOLTS |
| U | MICROVOLTS |
| L | MILLIVOLTS |
| V | VOLTS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AWNQ*DPOWER SUPPLY OUTPUT CURRENT TYPE
INDICATES THE TYPE OF POWER SUPPLY OUTPUT CURRENT PROVIDED.
Enter the applicable reply code from the table below
(AWNQDC*;AWNQDB$DD*)
| Table 1 |
| Reply Code (AB62) | Reply |
| B | AC |
| D | AC/DC |
| C | DC |
AWNP*JPOWER SUPPLY OUTPUT VOLTAGE RATING
THE VALUE,OR RANGE OF VALUES,OF OUTPUT OF THE POWER SUPPLY.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AWNPJVA2.0*;AWNPJVA2.0$$JVA2.1*)
| Table 1 |
| Reply Code (AB63) | Reply |
| K | KILOVOLTS |
| M | MEGAVOLTS |
| U | MICROVOLTS |
| L | MILLIVOLTS |
| V | VOLTS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AWNR*JPOWER SUPPLY OUTPUT CURRENT RATING
THE OUTPUT CURRENT RATING OF THE POWER SUPPLY.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AWNRJUA2.0*;AWNRJUA2.0$$JUA2.1*)
| Table 1 |
| Reply Code (AC30) | Reply |
| A | AMPERES |
| U | MICROAMPERES |
| L | MILLIAMPERES |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABHP*JOVERALL LENGTH
THE DIMENSION MEASURED ALONG THE LONGITUDINAL AXIS WITH TERMINATED POINTS AT THE EXTREME ENDS OF THE ITEM.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABHPJAC2.0*;ABHPJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABMK*JOVERALL WIDTH
AN OVERALL MEASUREMENT TAKEN AT RIGHT ANGLES TO THE LENGTH OF AN ITEM,IN DISTINCTION FROM THICKNESS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABMKJAC2.0*;ABMKJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
HGTH*JHEIGHT
A MEASUREMENT FROM THE BOTTOM TO THE TOP OF AN OBJECT,IN DISTINCTION FROM DEPTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(HGTHJAC2.0*;HGTHJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABPX*JMATERIAL THICKNESS
A MEASUREMENT OF THE SMALLEST DIMENSION OF THE MATERIAL,IN DISTINCTION FROM LENGTH OR WIDTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABPXJAC2.0*;ABPXJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABFF*DFURNISHED ITEMS
ITEMS FURNISHED AS ACCESSORIES WHICH ARE NOT SPECIFIED ELSEWHERE.
Enter the applicable reply code from the table below
(ABFFDABR*;ABFFDBBZ$$DATC*)
| Table 1 |
| Reply Code (AB28) | Reply |
| BQN | ADHESIVE |
| BQQ | ANCHOR NUT |
| BQP | ANGLE |
| AEG | BALL BEARING |
| ABR | BOLT |
| AJM | BUSHING |
| AEL | CAP |
| AYK | CHANNEL |
| BBZ | CLEVIS |
| ASX | CLIP |
| BCA | COTTER PIN |
| BQR | ELBOW |
| ACN | GASKET |
| AJR | INSERT |
| ARJ | LOCK RING |
| ABW | NUT |
| BQS | NUT PLATE |
| ABY | PIN |
| ATB | PLATE |
| AQW | RING |
| ATC | RIVET |
| AMX | SCREW |
| AFH | SEAL |
| BPQ | SHIM |
| ATD | SPACER |
| AMY | SPRING |
| AJW | WASHER |
CBBL*DFEATURES PROVIDED
THOSE FEATURES,NOT OTHERWISE SPECIFIED,WHICH MAY BE REQUIRED FOR PROPER FUNCTIONING OF THE ITEM.
Enter the applicable reply code from the table below
(CBBLDFNY)
| Table 1 |
| Reply Code (AN47) | Reply |
| FNY | ROHS DIRECTIVE COMPLIANCE |
FEAT*GSPECIAL FEATURES
THOSE UNUSUAL OR UNIQUE CHARACTERISTICS OR QUALITIES OF AN ITEM NOT COVERED IN THE OTHER REQUIREMENTS AND WHICH ARE DETERMINED TO BE ESSENTIAL FOR IDENTIFICATION ON ONE OR MORE OTHER FUNCTIONS.
Enter the reply in clear text. Separate multiple replies with a semicolon.
(FEATGADJUSTABLE NOSE CLIP*; FEATGADJUSTABLE NOSE PIECE; DISPOSABLE*)
ZZZK*JSPECIFICATION/STANDARD DATA
THE DOCUMENT DESIGNATOR OF THE SPECIFICATION OR STANDARD WHICH ESTABLISHED THE ITEM OF SUPPLY.
Enter the applicable Reply Code from the table below, followed by the Commercial and Government Entity (CAGE) Code of the entity controlling the document, a dash, and the document designator. The agency that controls the limited coordination document must be preceded and followed by a slash following the designator. The word canceled or superseded must be preceded and followed by a slash for the designator. Professional and industrial association specifications/standards are differentiated from a manufacturer's specification in that the data has been coordinated and published by the professional and industrial association. Include amendments and revisions where applicable.
(ZZZKJT81337-30642B*;ZZZKJS81349-MIL-D-180 REV1/CANCELED/*;ZZZKJP80205-NAS1103*;ZZZKJS81349-MIL-C-1140C/CE/*;ZZZKJT81337-30642B$$JP80205-NAS1103*)
| Table 1 |
| Reply Code (AN62) | Reply |
| S | GOVERNMENT SPECIFICATION |
| T | GOVERNMENT STANDARD |
| D | MANUFACTURERS SOURCE CONTROL |
| R | MANUFACTURERS SPECIFICATION |
| N | MANUFACTURERS SPECIFICATION CONTROL |
| M | MANUFACTURERS STANDARD |
| B | NATIONAL STD/SPEC |
| A | PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
| P | PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
If the specification/standard cited in reply to MRC ZZZK is nondefinitive, reply to MRC ZZZT. This reply is the data which is not recorded in Segment C.
ZZZT*JNONDEFINITIVE SPEC/STD DATA
THE NUMBER, LETTER, OR SYMBOL INDICATING THE TYPE, STYLE, GRADE, CLASS, AND THE LIKE OF AN ITEM IN A NONIDENTIFYING SPECIFICATION OR STANDARD.
Enter the applicable Reply Code from the table below followed by the appropriate number, letter or symbol.
(ZZZTJTY1*; ZZZTJTY1$$JSTA*; ZZZTJTY1$JSTA*)
| Table 1 |
| Reply Code (AD08) | Reply |
| AL | ALLOY |
| AN | ANNEX |
| AP | APPENDIX |
| AC | APPLICABILITY CLASS |
| AR | ARRANGEMENT |
| AS | ASSEMBLY |
| AB | ASSORTMENT |
| BX | BOX |
| CY | CAPACITY |
| CA | CASE |
| CT | CATEGORY |
| CL | CLASS |
| CE | CODE |
| CR | COLOR |
| CC | COMBINATION CODE |
| CN | COMPONENT |
| CP | COMPOSITION |
| CM | COMPOUND |
| CD | CONDITION |
| CS | CONSTRUCTION |
| DE | DESIGN |
| DG | DESIGNATOR |
| DW | DRAWING NUMBER |
| EG | EDGE |
| EN | END |
| FY | FAMILY |
| FG | FIGURE |
| FN | FINISH |
| FM | FORM |
| FA | FORMULA |
| GR | GRADE |
| GP | GROUP |
| BA | IMAGE COLOR |
| NS | INSERT |
| TM | ITEM |
| KD | KIND |
| KT | KIT |
| LG | LENGTH |
| LT | LIMIT |
| MK | MARK |
| AA | MARKER |
| ML | MATERIAL |
| BB | MAXIMUM DENSITY |
| MH | MESH |
| ME | METHOD |
| BC | MINIMUM DENSITY |
| MD | MODEL |
| MT | MOUNTING |
| NR | NUMBER |
| PT | PART |
| PN | PATTERN |
| PC | PHYSICAL CONDITION |
| PS | PIECE |
| PL | PLAN |
| PR | POINT |
| QA | QUALITY |
| RN | RANGE |
| RT | RATING |
| RF | REFERENCE NUMBER |
| SC | SCHEDULE |
| SB | SECTION |
| SL | SELECTION |
| SE | SERIES |
| SV | SERVICE |
| SX | SET |
| SA | SHADE |
| SH | SHAPE |
| SG | SHEET |
| SZ | SIZE |
| PZ | SPECIES |
| SQ | SPECIFICATION SHEET |
| SD | SPEED |
| ST | STYLE |
| SS | SUBCLASS |
| SF | SUBFORM |
| SP | SUBTYPE |
| SN | SURFACE CONDITION |
| SY | SYMBOL |
| SM | SYSTEM |
| TB | TABLE |
| TN | TANNAGE |
| TP | TEMPER |
| TX | TEXTURE |
| TK | THICKNESS |
| TT | TREATMENT |
| TR | TRIM |
| TY | TYPE |
| YN | UNIT |
| VA | VARIETY |
| WT | WEIGHT |
| WD | WIDTH |
ZZZY*GREFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS
A FEATURE OF THE ITEM OF SUPPLY WHICH MUST BE SPECIFICALLY RECORDED WHEN THE REFERENCE NUMBER COVERS A RANGE OF ITEMS.
Enter the reply in clear text.
(ZZZYGCOLOR CODED LEADS*; ZZZYGAS DIFFERENTIATED BY MATERIAL*)
Reply to this requirement only if the header record for the item identification for the item being identified has been coded as critical.
CRTL*ACRITICALITY CODE JUSTIFICATION
THE MASTER REQUIREMENT CODES OF THOSE REQUIREMENTS WHICH ARE TECHNICALLY CRITICAL BY REASON OF TOLERANCE,FIT,PERFORMANCE,OR OTHER CHARACTERISTICS WHICH AFFECT IDENTIFICATION OF THE ITEM.
Enter the Master Requirement Code for the requirement, the reply to which renders the item as being critical.
(CRTLAAKJA*; CRTLAAKJA$$ACSGS*)
If document availability code B, D, F, OR H, reply to MRC PRPY.
PRPY*APROPRIETARY CHARACTERISTICS
IDENTIFICATION OF THOSE CHARACTERISTICS INCLUDED IN THE DESCRIPTION FOR WHICH A NON-GOVERNMENT ACTIVITY HAS IDENTIFIED ALL OR SELECTED CHARACTERISTICS OF THE ITEM AS BEING PROPRIETARY AND THEREFORE RESTRICTED FROM RELEASE OUTSIDE THE GOVERNMENT WITHOUT PRIOR PERMISSION OF THE ORIGINATOR OF THE DATA.
Enter the MRC codes of the individual characteristics of the description which are marked proprietary on the technical data, using and coding ($) for multiple characteristics. If all the MRCS are proprietary, enter the reply PACS. If none of the MRCS is proprietary, enter the reply NPAC.
(PRPYAPACS*;PRPYANPAC*; PRPYAMATL$$ASURF*)
ELRN*GEXTRA LONG REFERENCE NUMBER
A REFERENCE NUMBER EXCEEDING 32 POSITIONS.
Enter the entire reference number. Do not include the 5-position Commercial and Government Entity (CAGE) Code unless there is more than one extra long reference number on the NSN.If there is more than one extra long reference number on the NSN, include the CAGE or NCAGE and separate each reference by using the "&" character.
(e.g., CAGE112036BIL060557LEN313605UZ62365 & CAGE112036BIL060557LEN313605UZ62365)
In determining quantity of characters in the reference number, count will be made after modification in accordance with Volume 2, Chapter 9, FLIS Procedures Manual, DoD 4100.39-M.
Reply to this MRC in accordance with Volume 3.
AGAV*GEND ITEM IDENTIFICATION
THE NATIONAL STOCK NUMBER OR THE IDENTIFICATION INFORMATION OF THE END EQUIPMENT FOR WHICH THE ITEM IS A PART.
Enter the reply in clear text.
(AGAVG3930-00-000-0000*; AGAVGFORKLIFT TRUCK, SMITH CORPORATION, MODEL 12, TYPE A*)
CXCY*GPART NAME ASSIGNED BY CONTROLLING AGENCY
THE NAME ASSIGNED TO THE ITEM BY THE GOVERNMENT AGENCY OR COMMERCIAL ORGANIZATION CONTROLLING THE DESIGN OF THE ITEM.
Enter the reply in clear text.
(CXCYGLINE PROCESSOR CONTROL BOARD*)
CLQL*GCOLLOQUIAL NAME
A COMMON USAGE NAME BY WHICH AN ITEM IS KNOWN.
Enter the reply in clear text.
(CLQLGWOVEN WIRE CLOTH*)