An electrical item (the working element of which is constructed essentially of metallic substances) which changes alternating current to direct current by the rectifying action occurring at the junction interface between a metallic conductor and a semiconductor. Excludes:sets of metallic rectifiers which are not rated for rectifying capabilities but are used as suppressors. For items containing germanium or silicon, see SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET and RECTIFIER, SEMICONDUCTOR DEVICE. For a complete power supply utilizing metallic rectifiers, see POWER SUPPLY.
NAMEDITEM NAME
NOUN, WITH OR WITHOUT MODIFIERS, BY WHICH AN ITEM OF SUPPLY IS KNOWN.
Enter the item name code.
(NAMED00299*)
MATTDMATERIAL
THE CHEMICAL COMPOUND OR MECHANICAL MIXTURE PROPERTIES OF WHICH THE ITEM IS FABRICATED.
Enter the applicable reply code from the table below
(MATTDAGA000*;MATTDMTH000$DALA000*;MATTDMTH000$$DALA000*)
| Table 1 |
| Reply Code (MA01) | Reply |
| ALA000 | ALUMINUM |
| CUA000 | COPPER |
| GSA000 | GLASS |
| PCA000 | PLASTIC |
| MTH000 | SELENIUM |
| SLC000 | SILICON |
| AGA000 | SILVER |
Reply to this requirement only if the MRC for Material has been answered and there is additional standard specifications that need to be identified on the Material reply.
MDCL*JMATERIAL DOCUMENT AND CLASSIFICATION
THE SPECIFICATION, STANDARD, OR MANUFACTURER'S REFERENCE AND THE CLASSIFICATION DESIGNATION, SUCH AS CLASS, CONDITION, TEMPER, AND THE LIKE, THAT IDENTIFIES THE MATERIAL.
Enter the applicable Reply Code from Tables 1 & 2 below followed by an alpha-numeric reply with a minimum of one character as in the first, second, and third examples. If ISAC coding is authorized for this requirement, enter the applicable ISAC from Table 1 below followed by the mode code and applicable Reply Code from Tables 2 & 3 below followed by an alpha-numeric reply with a minimum of one character as in the fourth, fifth, and sixth examples.
(MDCLJEATEXT1234*;MDCLJEATEXT1234$$JEATEXT1234*;MDCLJEATEXT1234$JEATEXT1234*;MDCL1BJEATEXT1234*;MDCL1BJEATEXT1234$$JEATEXT1234*;MDCL1BJEATEXT1234$JEATEXT1234*)
| Table 1 |
| Reply Code (AP33) | Reply |
| Q | AEROSPACE MATERIAL SPEC STD |
| J | AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) |
| G | ASSN STD |
| A | COMMERCIAL ITEM DESCRIPTION |
| K | DEF STAN/SPEC |
| B | FED SPEC |
| C | FED STD |
| L | GOVERNMENT STD/SPEC |
| N | INTERNATIONAL STD/SPEC |
| F | MFR REF |
| D | MIL SPEC |
| E | MIL STD |
| H | NATIONAL SPEC |
| P | NATIONAL STD |
| M | NATIONAL STD/SPEC |
| Table 2 |
| Reply Code (AP18) | Reply |
| M | 10TH MATERIAL RESPONSE |
| N | 11TH MATERIAL RESPONSE |
| P | 12TH MATERIAL RESPONSE |
| Q | 13TH MATERIAL RESPONSE |
| R | 14TH MATERIAL RESPONSE |
| S | 15TH MATERIAL RESPONSE |
| T | 16TH MATERIAL RESPONSE |
| U | 17TH MATERIAL RESPONSE |
| W | 18TH MATERIAL RESPONSE |
| X | 19TH MATERIAL RESPONSE |
| B | 1ST MATERIAL RESPONSE |
| Y | 20TH MATERIAL RESPONSE |
| Z | 21ST MATERIAL RESPONSE |
| V | 22ND MATERIAL RESPONSE |
| C | 2ND MATERIAL RESPONSE |
| D | 3RD MATERIAL RESPONSE |
| E | 4TH MATERIAL RESPONSE |
| F | 5TH MATERIAL RESPONSE |
| H | 6TH MATERIAL RESPONSE |
| J | 7TH MATERIAL RESPONSE |
| K | 8TH MATERIAL RESPONSE |
| L | 9TH MATERIAL RESPONSE |
| G | ALL MATERIAL RESPONSES |
| A | SINGLE MATERIAL RESPONSE |
AJURLCIRCUIT CONNECTION STYLE DESIGNATOR
THE STYLE DESIGNATION INDICATING THE CONFIGURATION THAT MOST NEARLY CORRESPONDS TO THE APPEARANCE OF THE CIRCUIT CONNECTION.
Review the representative drawings below, find the drawing which best represents your item.Use the Physical Drawing ID (eg: AAT1001) to identify the row(s) in the table which are applicable to your drawing.Enter the applicable reply code from the table below.
(AJURLA10)
| Table 1 |
| Physical Drawing ID | Reply Code (STYL) | Reply |
| AAA1450 | A1 | HALF-WAVE 1 PHASE |
| AAA1459 | A10 | INVERTED CENTER TAP 1 PHASE |
| AAA1460 | A11 | MAGNETIC AMPLIFIER BRIDGE 1 PHASE |
| AAA1461 | A12 | OPEN BRIDGE 1 PHASE |
| AAA1462 | A13 | MAGNETIC AMPLIFIER OPEN BRIDGE 3 PHASE |
| AAA1451 | A2 | CENTER TAP 1 PHASE |
| AAA1452 | A3 | DOUBLER 1 PHASE |
| AAA1453 | A4 | TRIPLER 1 PHASE |
| AAA1454 | A5 | RING 1 PHASE |
| AAA1455 | A6 | HALF-WAVE 3 PHASE |
| AAA1456 | A7 | BRIDGE 1 PHASE |
| AAA1457 | A8 | BRIDGE 3 PHASE |
| AAA1458 | A9 | CENTER TAP 3 PHASE |
AARAATERMINAL QUANTITY
THE NUMBER OF TERMINALS FOR PROVIDING ELECTRICAL CONNECTION TO THE ITEM.
Enter the numeric reply with a minimum of one digit.
(AARAA10*)
ALAW*JABSOLUTE MAXIMUM VOLTAGE RATING IN VOLTS PER CHARACTERISTIC
THE MAXIMUM LIMITING VALUE OF THE VOLTAGE THAT MAY BE APPLIED AND THE SYMBOL USED TO IDENTIFY THE SPECIFIC ELECTRICAL CHARACTERISTIC,EXPRESSED IN VOLTS.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ALAWJBG2.0*;ALAWJBG2.0$$JBG2.1*)
| Table 1 |
| Reply Code (AH15) | Reply |
| BN | BASE SUPPLY VOLTAGE |
| BQ | BASE TO EMITTER SATURATION VOLTAGE |
| BP | BASE TO EMITTER VOLTAGE, DC |
| BY | BREAKDOWN VOLTAGE, COLLECTOR TO EMITTER, SUSTAINED |
| BR | BREAKDOWN VOLTAGE, COLLECTOR TO EMITTER, WITH SPECIFIED VOLTAGE BETWEEN BASE AND EMITTER |
| AB | BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN |
| AC | BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN |
| AE | BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, WITH BASE SHORT-CIRCUITED TO EMITTER |
| AF | BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, WITH SPECIFIED CIRCUIT BETWEEN BASE AND EMITTER |
| AD | BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, WITH SPECIFIED RESISTANCE BETWEEN BASE AND EMITTER |
| CT | BREAKDOWN VOLTAGE, DC |
| AG | BREAKDOWN VOLTAGE, DRAIN-TO-SOURCE, WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE |
| BM | BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN |
| AH | BREAKDOWN VOLTAGE, GATE-TO-BULK, WITH ALL OTHER TERMINALS OPEN-CIRCUITED |
| AJ | BREAKDOWN VOLTAGE, GATE-TO-SOURCE, WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE |
| CW | BREAKDOWN VOLTAGE, INSTANTANEOUS |
| DF | BREAKOVER VOLTAGE, DC |
| DG | BREAKOVER VOLTAGE, INSTANTANEOUS |
| BW | COLLECTOR SUPPLY VOLTAGE |
| AL | COLLECTOR TO BASE VOLTAGE, DC |
| AM | COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN |
| AQ | COLLECTOR TO EMITTER REVERSE VOLTAGE |
| AS | COLLECTOR TO EMITTER REVERSE VOLTAGE, WITH BASE SHORT-CIRCUITED TO EMITTER |
| AN | COLLECTOR TO EMITTER VOLTAGE, DC |
| AR | COLLECTOR TO EMITTER VOLTAGE, DC WITH BASE SHORT-CIRCUITED TO EMITTER |
| AT | COLLECTOR TO EMITTER VOLTAGE, DC WITH SPECIFIED CIRCUIT BETWEEN BASE AND EMITTER |
| AP | COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN |
| BT | DC, OPEN-CIRCUIT VOLTAGE, FLOATING POTENTIAL, BETWEEN THE COLLECTOR AND BASE, WITH THE EMITTER BIASED IN THE REVERSE DIRECTION WITH RESPECT TO THE BASE |
| CF | DRAIN SUPPLY VOLTAGE |
| AW | DRAIN TO GATE VOLTAGE |
| AX | DRAIN TO SOURCE VOLTAGE |
| CH | DRAIN TO SUBSTRATE VOLTAGE |
| CB | EMITTER SUPPLY VOLTAGE |
| AY | EMITTER TO BASE VOLTAGE, DC |
| AZ | EMITTER TO BASE VOLTAGE, FLOATING POTENTIAL, DC WITH COLLECTOR BIASED IN REVERSE DIRECTION WITH RESPECT TO THE BASE |
| CA | EMITTER TO BASE VOLTAGE, INSTANTANEOUS |
| BA | EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN |
| BZ | EMITTER TO BASE, RMS |
| BB | EMITTER TO COLLECTOR VOLTAGE, DC |
| BC | EMITTER TO COLLECTOR VOLTAGE, FLOATING POTENTIAL, DC WITH BASE BIASED IN REVERSE DIRECTION WITH RESPECT TO THE COLLECTOR |
| CD | FORWARD GATE TO SOURCE BREAKDOWN VOLTAGE |
| CL | FORWARD GATE TO SOURCE VOLTAGE |
| CX | FORWARD VOLTAGE, AVERAGE |
| CY | FORWARD VOLTAGE, PEAK |
| CZ | FORWARD VOLTAGE, TOTAL RMS |
| DT | GATE NON-TRIGGER VOLTAGE, DC |
| DW | GATE NON-TRIGGER VOLTAGE, INSTANTANEOUS |
| CJ | GATE SUPPLY VOLTAGE |
| CN | GATE TO SOURCE CUTOFF VOLTAGE |
| CP | GATE TO SOURCE THRESHOLD VOLTAGE |
| CK | GATE TO SOURCE VOLTAGE |
| CQ | GATE TO SUBSTRATE VOLTAGE |
| DZ | GATE TRIGGER VOLTAGE, DC |
| EA | GATE TRIGGER VOLTAGE, INSTANTANEOUS |
| DR | GATE VOLTAGE, DC |
| DS | GATE VOLTAGE, INSTANTANEOUS |
| EP | INFLECTION-POINT VOLTAGE |
| AK | INTERBASE VOLTAGE |
| ET | NOMINAL REGULATOR VOLTAGE |
| DQ | NONREPETITIVE PEAK OFF-STATE VOLTAGE |
| DD | NONREPETITIVE PEAK REVERSE VOLTAGE |
| BF | NONREPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE |
| BK | NONREPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE, GATE TERMINAL OPEN-CIRCUITED |
| DK | OFF-STATE VOLTAGE, DC |
| DL | OFF-STATE VOLTAGE, INSTANTANEOUS |
| DM | OFF-STATE VOLTAGE, PEAK |
| DN | OFF-STATE VOLTAGE, RMS TOTAL |
| BD | ON VOLTAGE, FORWARD VOLTAGE DROP, DC |
| CG | ON-STATE DRAIN TO SOURCE VOLTAGE |
| EK | ON-STATE VOLTAGE, AVERAGE |
| EH | ON-STATE VOLTAGE, DC |
| EJ | ON-STATE VOLTAGE, INSTANTANEOUS |
| EL | ON-STATE VOLTAGE, PEAK |
| EM | ON-STATE VOLTAGE, RMS TOTAL |
| DY | PEAK NEGATIVE GATE VOLTAGE |
| DX | PEAK POSITIVE GATE VOLTAGE |
| EQ | PEAK-POINT VOLTAGE |
| ES | PROJECTED LIMIT PEAK-POINT VOLTAGE |
| EN | PROJECTED PEAK-POINT VOLTAGE |
| CC | REACH THROUGH VOLTAGE |
| DP | REPETITIVE PEAK OFF-STATE VOLTAGE |
| DC | REPETITIVE PEAK REVERSE VOLTAGE |
| BG | REPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE |
| BJ | REPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE, GATE TERMINAL OPEN-CIRCUITED |
| DH | REVERSE BREAKDOWN VOLTAGE, DC |
| DJ | REVERSE BREAKDOWN VOLTAGE, INSTANTANEOUS |
| CE | REVERSE GATE TO SOURCE BREAKDOWN VOLTAGE |
| CM | REVERSE GATE TO SOURCE VOLTAGE |
| DA | REVERSE VOLTAGE, AVERAGE |
| BE | REVERSE VOLTAGE, DC |
| EC | REVERSE VOLTAGE, INSTANTANEOUS |
| ED | REVERSE VOLTAGE, PEAK |
| DB | REVERSE VOLTAGE, TOTAL RMS |
| CR | SOURCE SUPPLY VOLTAGE |
| CS | SOURCE TO SUBSTRATE VOLTAGE |
| ER | VALLEY-POINT VOLTAGE |
| DE | WORKING PEAK REVERSE VOLTAGE |
| BH | WORKING PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE |
| BL | WORKING PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE, GATE TERMINAL OPEN-CIRCUITED |
AXGY*DMOUNTING METHOD
THE MEANS OF ATTACHING THE ITEM.
Enter the applicable reply code from the table below
(AXGYDACD*;AXGYDACP$DAEF*;AXGYDACP$$DAEF*)
| Table 1 |
| Reply Code (AM39) | Reply |
| ABB | BASE |
| AQS | BODY |
| AAC | BOLT |
| ABC | BRACKET |
| ABH | CLAMP |
| AFL | CLIP |
| ACP | HOLE |
| AEF | SOCKET |
| AAE | STUD |
| ACD | TERMINAL |
CSCF*DTERMINAL TYPE
INDICATES THE TYPE OF TERMINAL FOR PROVIDING ELECTRICAL CONNECTION TO THE ITEM.
Enter the applicable reply code from the table below
(CSCFDASP*;CSCFDAFF$DACC*;CSCFDAFF$$DACC*)
| Table 1 |
| Reply Code (AN89) | Reply |
| ABL | BINDING POST |
| ASN | BOLT HOLE |
| ABM | BRACKET |
| AEM | BUS BAR |
| ACN | CONNECTOR, PLUG |
| AAF | CONNECTOR, RECEPTACLE |
| AAH | FERRULE |
| ASC | FERRULE W/WIRE LEAD |
| ASJ | HOLE |
| AHX | LUG |
| AAM | PIN |
| ADA | QUICK DISCONNECT, FEMALE |
| ACZ | QUICK DISCONNECT, MALE |
| ABQ | SCREW |
| ABT | SCREW BASE |
| ASP | SCREW W/TERMINAL LUG |
| AFF | SOLDER LUG |
| ASM | SOLDER LUG W/WIRE LEAD |
| ALK | SOLDER POST |
| AAS | SOLDER STUD |
| AEK | SOLDERLESS LUG |
| ASQ | SPADE LUG |
| AJA | STUD |
| ASR | STUD W/TERMINAL LUG |
| AFW | TAB |
| ABX | TAB W/SCREW |
| AKC | TERMINAL LUG |
| ABD | THREADED STUD |
| ABF | UNINSULATED WIRE LEAD |
| ABJ | WIRE BRAID |
| ACC | WIRE LEAD |
| ASS | WIRE LEAD W/TERMINAL LUG |
ALAY*JABSOLUTE MAXIMUM CURRENT RATING PER CHARACTERISTIC
THE LIMITING VALUE OF CURRENT THAT MAY FLOW AND THE SPECIFIC ELECTRICAL CHARACTERISTIC.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ALAYJADR2.0*;ALAYJADR2.0$$JADR2.1*)
| Table 1 |
| Reply Code (AC30) | Reply |
| A | AMPERES |
| U | MICROAMPERES |
| L | MILLIAMPERES |
| Table 2 |
| Reply Code (AH16) | Reply |
| CG | AVERAGE FORWARD CURRENT AVERAGED OVER A FULL 60-HZ CYCLE |
| DX | AVERAGE GATE POWER DISSIPATION |
| DM | AVERAGE ON-STATE CURRENT, 180 DEGREES CONDUCTION ANGLE, AVERAGE OVER A FULL 60-HZ CYCLE |
| AB | BASE CURRENT, DC |
| BD | BASE CURRENT, INSTANTANEOUS |
| CQ | BREAKOVER CURRENT, DC |
| CR | BREAKOVER CURRENT, INSTANTANEOUS |
| AC | COLLECTOR CURRENT, DC |
| BE | COLLECTOR CURRENT, INSTANTANEOUS |
| BG | COLLECTOR CUTOFF CURRENT, DC, BASE OPEN |
| BF | COLLECTOR CUTOFF CURRENT, DC, EMITTER OPEN |
| BK | COLLECTOR CUTOFF CURRENT, DC, WITH BASE SHORT-CIRCUITED TO EMITTER |
| BJ | COLLECTOR CUTOFF CURRENT, DC, WITH SPECIFIED CIRCUIT BETWEEN BASE AND EMITTER |
| BH | COLLECTOR CUTOFF CURRENT, DC, WITH SPECIFIED RESISTANCE BETWEEN BASE AND EMITTER |
| BM | COLLECTOR POWER DISSIPATION |
| AD | DRAIN CURRENT |
| BQ | DRAIN CUTOFF CURRENT |
| AE | EMITTER CURRENT, DC |
| BL | EMITTER CUTOFF CURRENT, DC, COLLECTOR OPEN |
| CC | FORWARD CURRENT, AVERAGE |
| AF | FORWARD CURRENT, DC |
| AG | FORWARD CURRENT, MAXIMUM PEAK TOTAL VALUE |
| AH | FORWARD CURRENT, NONREPETITIVE, MAXIMUM PEAK TOTAL VALUE |
| AJ | FORWARD CURRENT, REPETITIVE, MAXIMUM PEAK TOTAL VALUE |
| CD | FORWARD CURRENT, TOTAL RMS |
| BS | FORWARD GATE CURRENT |
| BX | FORWARD GATE CURRENT WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE, INSULATED-GATE |
| AL | GATE 1 CURRENT |
| AM | GATE 2 CURRENT |
| AK | GATE CURRENT |
| DB | GATE NON-TRIGGER CURRENT, DC |
| DC | GATE NON-TRIGGER CURRENT, INSTANTANEOUS |
| DF | GATE TRIGGER CURRENT, DC |
| DG | GATE TRIGGER CURRENT, INSTANTANEOUS |
| DH | HOLDING CURRENT, DC |
| DJ | HOLDING CURRENT, INSTANTANEOUS |
| AN | INFLECTION POINT CURRENT |
| DK | LATCHING CURRENT, DC |
| DL | LATCHING CURRENT, INSTANTANEOUS |
| EA | MAXIMUM DC CURRENT IN REVERSE BREAKDOWN REGION |
| EB | MAXIMUM REVERSE SURGE CURRENT |
| CW | OFF-STATE CURRENT, DC |
| CX | OFF-STATE CURRENT, INSTANTANEOUS |
| CY | OFF-STATE CURRENT, PEAK |
| CZ | OFF-STATE CURRENT, RMS TOTAL |
| DQ | ON-STATE CURRENT, AVERAGE |
| DN | ON-STATE CURRENT, DC |
| DP | ON-STATE CURRENT, INSTANTANEOUS |
| DR | ON-STATE CURRENT, PEAK |
| DS | ON-STATE CURRENT, RMS TOTAL |
| BP | ON-STATE DRAIN CURRENT |
| CF | PEAK FORWARD SURGE CURRENT |
| DY | PEAK GATE POWER DISSIPATION |
| DE | PEAK NEGATIVE GATE CURRENT |
| DW | PEAK ON-STATE SURGE CURRENT |
| AP | PEAK POINT CURRENT |
| DD | PEAK POSITIVE GATE CURRENT |
| AQ | PEAK PULSE CURRENT |
| DA | PEAK REPETITIVE OFF-STATE CURRENT |
| CP | PEAK REVERSE SURGE CURRENT |
| CE | REPETITIVE PEAK FORWARD CURRENT |
| DT | REPETITIVE PEAK ON-STATE CURRENT |
| CN | REPETITIVE PEAK REVERSE CURRENT |
| CS | REVERSE BREAKDOWN CURRENT, DC |
| CT | REVERSE BREAKDOWN CURRENT, INSTANTANEOUS |
| CK | REVERSE CURRENT, AVERAGE |
| CH | REVERSE CURRENT, DC |
| CJ | REVERSE CURRENT, INSTANTANEOUS |
| CL | REVERSE CURRENT, PEAK |
| CM | REVERSE CURRENT, TOTAL RMS |
| BT | REVERSE GATE CURRENT |
| BW | REVERSE GATE CURRENT WITH ALL OTHER TERMINALS SHORT-CIRCUIT TO SOURCE, JUNCTION-GATE |
| BY | REVERSE GATE CURRENT WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE, INSULATED-GATE |
| BZ | SOURCE CURRENT |
| CA | SOURCE CUTOFF CURRENT |
| BN | TOTAL POWER DISSIPATION |
| AR | VALLEY POINT CURRENT |
| AS | VOLTAGE REGULATOR DIODE CURRENT |
| DZ | VOLTAGE REGULATOR DIODE CURRENT NEAR BREAKDOWN KNEE |
| BR | ZERO-GATE-VOLTAGE DRAIN CURRENT |
| CB | ZERO-GATE-VOLTAGE SOURCE CURRENT |
ALNT*JABSOLUTE MAXIMUM POWER RATING PER CHARACTERISTIC
THE MAXIMUM LIMITING VALUE OF ELECTRICAL POWER THAT MAY BE DISSIPATED AND THE SPECIFIC ELECTRICAL CHARACTERISTIC.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ALNTJATAJ2.0*)
| Table 1 |
| Reply Code (AB49) | Reply |
| BZ | MILLIWATTS |
| AT | WATTS |
| Table 2 |
| Reply Code (AH63) | Reply |
| AH | AVERAGE GATE POWER-FORWARD |
| AB | COLLECTOR POWER DISSIPATION |
| AK | FORWARD POWER DISSIPATION, AVERAGE |
| AC | FORWARD POWER DISSIPATION, DC |
| AD | FORWARD POWER DISSIPATION, MAXIMUM PEAK, TOTAL VALUE |
| AE | PEAK GATE POWER DISSIPATION |
| AJ | PEAK GATE POWER-FORWARD |
| AN | REVERSE POWER DISSIPATION, AVERAGE |
| AL | REVERSE POWER DISSIPATION, DC |
| AM | REVERSE POWER DISSIPATION, INSTANTANEOUS |
| AP | REVERSE POWER DISSIPATION, PEAK |
| AG | TOTAL DEVICE DISSIPATION |
| AF | TOTAL POWER DISSIPATION |
ALNW*BTEMP IN DEG CELSIUS AT WHICH ABSOLUTE MAXIMUM POWER RATING IS ESTABLISHED
THE TEMPERATURE AT WHICH THE ABSOLUTE MAXIMUM POWER DISSIPATION CAPABILITIES OF THE ITEM ARE ESTABLISHED,EXPRESSED IN DEGREES CELSIUS.
Enter a reply with a minimum of one digit on either side of the decimal point.
(ALNWB2.0)
ASCT*JRMS INPUT MAXIMUM VOLTAGE RATING
THE HIGHEST VALUE OF ROOT MEAN SQUARE POTENTIAL THAT CAN BE INPUT TO THE ITEM.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ASCTJK2.0*)
| Table 1 |
| Reply Code (AB63) | Reply |
| K | KILOVOLTS |
| V | VOLTS |
ASCW*JDC OUTPUT MAXIMUM CURRENT RATING
THE MAXIMUM AMOUNT OF DIRECT CURRENT THE ITEM IS DESIGNED TO OUTPUT.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ASCWJU2.0*)
| Table 1 |
| Reply Code (AC30) | Reply |
| A | AMPERES |
| U | MICROAMPERES |
| L | MILLIAMPERES |
ASCX*DLOAD TYPE
INDICATES THE TYPE OF LOAD FOR WHICH THE ITEM IS DESIGNED.
Enter the applicable reply code from the table below
(ASCXDAC*;ASCXDAE$DAD*;ASCXDAE$$DAD*)
| Table 1 |
| Reply Code (AK53) | Reply |
| AE | CAPACITIVE |
| AD | INDUCTIVE |
| AC | RESISTIVE |
AKGU*LINDIVIDUAL STACK CIRCUIT CONNECTION STYLE DESIGNATOR
THE STYLE DESIGNATION INDICATING THE CONFIGURATION THAT MOST NEARLY CORRESPONDS TO THE APPEARANCE OF THE INDIVIDUAL STACK CIRCUIT CONNECTION.
Review the representative drawings below, find the drawing which best represents your item.Use the Physical Drawing ID (eg: AAT1001) to identify the row(s) in the table which are applicable to your drawing.Enter the applicable reply code from the table below.
(AKGUL12*;AKGUL11$$L8*)
| Table 1 |
| Physical Drawing ID | Reply Code (STYL) | Reply |
| AAA1450 | 1 | HALF-WAVE 1 PHASE |
| AAA1459 | 10 | INVERTED CENTER TAP 1 PHASE |
| AAA1460 | 11 | MAGNETIC AMPLIFIER BRIDGE 1 PHASE |
| AAA1461 | 12 | OPEN BRIDGE 1 PHASE |
| AAA1462 | 13 | MAGNETIC AMPLIFIER OPEN BRIDGE 3 PHASE |
| AAA1451 | 2 | CENTER TAP 1 PHASE |
| AAA1452 | 3 | DOUBLER 1 PHASE |
| AAA1453 | 4 | TRIPLER 1 PHASE |
| AAA1454 | 5 | RING 1 PHASE |
| AAA1455 | 6 | HALF-WAVE 3 PHASE |
| AAA1456 | 7 | BRIDGE 1 PHASE |
| AAA1457 | 8 | BRIDGE 3 PHASE |
| AAA1458 | 9 | CENTER TAP 3 PHASE |
ASCZ*ASTACK QUANTITY
THE NUMBER OF STACKS IN THE ITEM.
Enter the numeric reply with a minimum of one digit.
(ASCZA10*)
ABJH*JTEMP RATING
A VALUE WHICH EXPRESSES THE DEGREE OF HEAT OR COLD AS APPLIED TO THE OPERATION,OR LIMITATION OF OPERATION,OF AN ITEM.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit as in the first and second examples.For negative temperature values, precede the numeric portion of the reply with the letter “M” as in the third and fourth examples.If ISAC coding is authorized for this requirement and one or more of the temperature values in negative, enter the applicable ISAC from Table 1 below followed by the mode code and applicable Reply Code from Table 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.Also precede the numeric portion of the reply with the letter “M” as in the fifth and sixth examples.
(ABJHJF68.0*; ABJHJC0.0$$JC35.0*; ABJHJFCM15.0*; ABJHJFM40.0$$JF75.0*; ABJH1BJFM25.0*; ABJH1BJCM35.0$$JCM5.0*)
| Table 1 |
| Reply Code (AB36) | Reply |
| C | CELSIUS |
| F | FAHRENHEIT |
ADZC*DENVIRONMENTAL PROTECTION
THE ENVIRONMENTAL ELEMENTS OR CONDITIONS THAT AN ITEM IS DESIGNED OR PROTECTED TO RESIST OR WITHSTAND SATISFACTORILY.
Enter the applicable reply code from the table below
(ADZCDJP*;ADZCDAP$$DCY*)
| Table 1 |
| Reply Code (AA65) | Reply |
| JP | ACID FUME |
| FT | ALKALI RESISTANT |
| AC | CORROSION |
| JQ | CORROSIVE FUME |
| CR | DRIPPROOF |
| BV | DUSTPROOF |
| EB | FUNGUS |
| EC | FUNGUS AND CORROSION |
| CY | HEAT RESISTANT |
| JR | HIGH HUMIDITY |
| BD | HIGH TEMPERATURE |
| GR | HUMIDITY RESISTANT |
| JS | MERCURY VAPOR |
| BZ | MOISTURE |
| CG | OIL IMMERSED |
| AK | OIL RESISTANT |
| JD | SALT AIR RESISTANT |
| GW | SALT SPRAY RESISTANT |
| JN | TROPICALIZED |
| AP | WATER, SALT |
ANPZ*DENCLOSURE FEATURE
AN INDICATION OF THE FEATURE/S/ OF THE ENCLOSURE.
Enter the applicable reply code from the table below
(ANPZDADK*;ANPZDADZ$DAEC*;ANPZDADZ$$DAEC*)
| Table 1 |
| Reply Code (AJ95) | Reply |
| ADJ | ALUMINUM CASE |
| ADK | ARC RESISTANT PLASTIC CASE |
| ADL | BAKELITE CASE |
| ADM | BRASS CASE |
| ADN | CARDBOARD CASE |
| ADP | CERAMIC CASE |
| ADQ | ENCAPSULATED |
| ADR | ENCASED |
| ADS | EPOXY CASE |
| ADT | EPOXY RESIN CASE |
| ADW | FIBER CASE |
| ADX | FIBERGLASS CASE |
| AAZ | FULLY ENCLOSED |
| ADY | GLASS CASE |
| ADZ | GLASS TUBE |
| AAK | HERMETICALLY SEALED |
| AEA | INSULATED CASE |
| AEB | LOW LOSS PLASTIC CASE |
| AEC | MELAMINE CASE |
| AED | METAL CASE |
| AEE | METALIZED GLASS CASE |
| AEF | NYLON CASE |
| ABA | PARTIALLY ENCLOSED |
| AEG | PHENOLIC CASE |
| AEH | PLASTIC CASE |
| AGH | UNENCLOSED |
ABHP*JOVERALL LENGTH
THE DIMENSION MEASURED ALONG THE LONGITUDINAL AXIS WITH TERMINATED POINTS AT THE EXTREME ENDS OF THE ITEM.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABHPJAB2.0*;ABHPJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABMK*JOVERALL WIDTH
AN OVERALL MEASUREMENT TAKEN AT RIGHT ANGLES TO THE LENGTH OF AN ITEM,IN DISTINCTION FROM THICKNESS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABMKJAB2.0*;ABMKJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABKW*JOVERALL HEIGHT
THE DISTANCE MEASURED IN A STRAIGHT LINE FROM THE BOTTOM TO THE TOP OF AN ITEM.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABKWJAC2.0*;ABKWJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ADAV*JOVERALL DIAMETER
A MEASUREMENT OF THE LONGEST STRAIGHT LINE ACROSS A CIRCULAR CROSS-SECTIONAL PLANE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ADAVJAC2.0*;ADAVJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ASDB*JWIDTH ACROSS FLATS
THE SHORTEST STRAIGHT LINE BETWEEN FLATS,PERPENDICULAR TO THE HEIGHT.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ASDBJAB2.0*;ASDBJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CTJZ*JSTACK OVERALL LENGTH
THE DIMENSION MEASURED ALONG THE LONGITUDINAL AXIS BETWEEN THE FIRST AND LAST PLATE WITH TERMINATED POINTS AT THE EXTREME ENDS OF THE STACK(S).
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CTJZJAA2.0*;CTJZJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ALGC*GMOUNTING CONFIGURATION
THE PATTERN OR ARRANGEMENT THAT DESCRIBES THE MOUNTING CONFIGURATION OF THE ITEM.
Enter clear text.
(ALGCGCLEARTEXT)
TEST*JTEST DATA DOCUMENT
THE SPECIFICATION,STANDARD,DRAWING,OR SIMILAR INSTRUMENT THAT SPECIFIES ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS OR TEST CONDITIONS UNDER WHICH AN ITEM IS TESTED AND ESTABLISHES ACCEPTABLE LIMITS WITHIN WHICH THE ITEM MUST CONFORM IDENTIFIED BY AN ALPHABETIC AND/OR NUMERIC REFERENCE NUMBER. INCLUDES THE COMMERCIAL AND GOVERNMENT ENTITY (CAGE) CODE OF THE ENTITY CONTROLLING THE INSTRUMENT.
Enter the applicable Reply Code from the table below, followed by the 5-position CAGE Code, a dash, and the document identification number.
(TESTJA12345-CWX654321*; TESTJA1234A-654321$$JB5556A-663654*; TESTJAA2345-654321$JB55566-663654*)
| Table 1 |
| Reply Code (AC28) | Reply |
| A | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| B | STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| C | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
SPCL*GSPECIAL TEST FEATURES
TEST CONDITIONS AND RATINGS OR ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS THAT ARE DIFFERENT, MORE CRITICAL, OR MORE SPECIFIC THAN THOSE SPECIFIED IN A GOVERNING TEST DATA DOCUMENT.
Enter the reply in clear text.
(SPCLGSELECTED AND TESTED FOR NAVIGATIONAL SYSTEMS*)
ZZZW*GDEPARTURE FROM CITED DOCUMENT
THE TECHNICAL DIFFERENTIATING CHARACTERISTIC(S) OF AN ITEM OF SUPPLY THAT DEPART(S) FROM THE TEXT OF A SPECIFICATION OR A STANDARD IN THAT IT REPRESENTS A SELECTION OF CHARACTERISTICS STATED IN THE SPECIFICATION OR STANDARD AS BEING OPTIONAL OR A VARIATION FROM ONE OR MORE OF THE STATED CHARACTERISTICS OR AN ADDITIONAL CHARACTERISTIC NOT STATED IN THE SPECIFICATION OR STANDARD.
Enter the reply in clear text.
(ZZZWGAS MODIFIED BY MATERIAL*)
ZZZX*GDEPARTURE FROM CITED DESIGNATOR
THE VARIATION WHEN THE ITEM IS IN CONFORMITY WITH A TYPE DESIGNATOR COVERED BY A SPECIFICATION OR STANDARD, EXCEPT IN REGARD TO ONE OR MORE TECHNICAL DIFFERENTIATING CHARACTERISTICS.
Enter the reply in clear text.
(ZZZXGAS MODIFIED BY MATERIAL*)
NHCF*DNUCLEAR HARDNESS CRITICAL FEATURE
AN INDICATION OF THE NUCLEAR HARDNESS CRITICALITY OF THE ITEM.
Enter the applicable reply code from the table below
(NHCFDCY)
| Table 1 |
| Reply Code (AD05) | Reply |
| CY | HARDENED |
ELCD*DEXTRA LONG CHARACTERISTIC DESCRIPTION
A DESCRIPTION THAT EXCEEDS 5000 CHARACTERS.
Enter the Reply Code from the table below.
(ELCDDA*)
| Table 1 |
| Reply Code (AN58) | Reply |
| A | ADDITIONAL DESCRIPTIVE DATA ON MANUAL RECORD |
CBME*JCUBIC MEASURE
A MEASUREMENT OF VOLUME TAKEN BY MULTIPLYING THE LENGTH BY THE WIDTH BY THE HEIGHT OF AN ITEM AND RENDERED IN CUBIC UNITS.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CBMEJCC2.0*)
| Table 1 |
| Reply Code (AN76) | Reply |
| CC | CUBIC CENTIMETERS |
Reply to this MRC in accordance with Volume 3.
AGAV*GEND ITEM IDENTIFICATION
THE NATIONAL STOCK NUMBER OR THE IDENTIFICATION INFORMATION OF THE END EQUIPMENT FOR WHICH THE ITEM IS A PART.
Enter the reply in clear text.
(AGAVG3930-00-000-0000*; AGAVGFORKLIFT TRUCK, SMITH CORPORATION, MODEL 12, TYPE A*)
PRMT*DPRECIOUS MATERIAL
IDENTIFICATION OF THE PRECIOUS MATERIAL CONTAINED IN THE ITEM.
Enter the applicable reply code from the table below
(PRMTDAZA000*;PRMTDAUA000$DRTA000*;PRMTDAUA000$$DRTA000*)
| Table 1 |
| Reply Code (MA01) | Reply |
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
PMWT*JPRECIOUS MATERIAL AND WEIGHT
AN INDICATION OF THE PRECIOUS MATERIAL CONTAINED IN THE ITEM,AND THE AMOUNT PER A MEASUREMENT SCALE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(PMWTJRTA000E2.0*;PMWTJRTA000E2.0$$JRTA000E2.1*)
| Table 1 |
| Reply Code (MA01) | Reply |
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
| Table 2 |
| Reply Code (AG14) | Reply |
| E | GRAINS, TROY |
| R | GRAMS |
| F | OUNCES, TROY |
PMLC*JPRECIOUS MATERIAL AND LOCATION
AN INDICATION OF THE PRECIOUS MATERIAL AND ITS LOCATION IN THE ITEM.
Enter the applicable Reply Code from Table 1 below followed by a alpha-numeric reply with a minimum of one character.
(PMLCJIRA0002.0*;PMLCJIRA0002.0$JIRA0002.0*;PMLCJIRA0002.0$$JIRA0002.1*)
| Table 1 |
| Reply Code (MA01) | Reply |
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
SUPP*GSUPPLEMENTARY FEATURES
CHARACTERISTICS OR QUALITIES OF AN ITEM NOT COVERED IN ANY OTHER REQUIREMENT THAT ARE CONSIDERED ESSENTIAL INFORMATION FOR ONE OR MORE FUNCTIONS, EXCLUDING NSN ASSIGNMENT.
Enter the reply in clear text.Separate multiple replies with a semicolon.
(SUPPGMAY INCL HOLE IN UPPER SUPPORT FOR MTG DURING SHIPMENT* SUPPGMAY INCL HOLE IN UPPER SUPPORT FOR MTG DURING SHIPMENT; BLADE TIEDOWN*)
This MRC replaced MRC ZZZP
The FSCM identifies the manufacturer or Government agency whose number appears in the Part Number column. When an FSCM does not appear in the current issue of H4-1, H4-2, or H4-3 Cataloging Handbooks, the word "None" will appear in the FSCM column and the name and address of the manufacturer or Government agency will be shown in parentheses following the item description.
PDNB*APURCHASE DESCRIPTION IDENTIFICATION
THE CONTROLLING ACTIVITY AND IDENTIFICATION OF A DOCUMENT USED IN LIEU OF A SPECIFICATION IN THE PROCUREMENT OF AN ITEM OF SUPPLY.
Enter the manufacturers 5-Digit Commercial and Government Entity (CAGE) Code listed in the FEDERAL SUPPLY CODE FOR MANUFACTURERS (FSCM) handbook, followed by a dash and the identifying number of the document, followed by a dash and the identifying number of the document.
(ZZZPJ81A37-30624A*)
ZZZV*GFSC APPLICATION DATA
THE JUSTIFICATION FOR THE ASSIGNMENT OF A FEDERAL SUPPLY CLASS /FSC/ TO AN ITEM BASED ON THE CLASSIFICATION OF THE NEXT HIGHER CLASSIFIABLE ASSEMBLY.
Enter the name of the next higher classifiable assembly in clear text.
(ZZZVGFUEL SYSTEM, GASOLINE ENGINE, NONAIRCRAFT*)
FEAT*GSPECIAL FEATURES
THOSE UNUSUAL OR UNIQUE CHARACTERISTICS OR QUALITIES OF AN ITEM NOT COVERED IN THE OTHER REQUIREMENTS AND WHICH ARE DETERMINED TO BE ESSENTIAL FOR IDENTIFICATION ON ONE OR MORE OTHER FUNCTIONS.
Enter the reply in clear text. Separate multiple replies with a semicolon.
(FEATGADJUSTABLE NOSE CLIP*; FEATGADJUSTABLE NOSE PIECE; DISPOSABLE*)
ELRN*GEXTRA LONG REFERENCE NUMBER
A REFERENCE NUMBER EXCEEDING 32 POSITIONS.
Enter the entire reference number. Do not include the 5-position Commercial and Government Entity (CAGE) Code unless there is more than one extra long reference number on the NSN.If there is more than one extra long reference number on the NSN, include the CAGE or NCAGE and separate each reference by using the "&" character.
(e.g., CAGE112036BIL060557LEN313605UZ62365 & CAGE112036BIL060557LEN313605UZ62365)
In determining quantity of characters in the reference number, count will be made after modification in accordance with Volume 2, Chapter 9, FLIS Procedures Manual, DoD 4100.39-M.
Reply to this requirement only if the header record for the item identification for the item being identified has been coded as critical.
CRTL*ACRITICALITY CODE JUSTIFICATION
THE MASTER REQUIREMENT CODES OF THOSE REQUIREMENTS WHICH ARE TECHNICALLY CRITICAL BY REASON OF TOLERANCE,FIT,PERFORMANCE,OR OTHER CHARACTERISTICS WHICH AFFECT IDENTIFICATION OF THE ITEM.
Enter the Master Requirement Code for the requirement, the reply to which renders the item as being critical.
(CRTLAAKJA*; CRTLAAKJA$$ACSGS*)
If document availability code B, D, F, OR H, reply to MRC PRPY.
PRPY*APROPRIETARY CHARACTERISTICS
IDENTIFICATION OF THOSE CHARACTERISTICS INCLUDED IN THE DESCRIPTION FOR WHICH A NON-GOVERNMENT ACTIVITY HAS IDENTIFIED ALL OR SELECTED CHARACTERISTICS OF THE ITEM AS BEING PROPRIETARY AND THEREFORE RESTRICTED FROM RELEASE OUTSIDE THE GOVERNMENT WITHOUT PRIOR PERMISSION OF THE ORIGINATOR OF THE DATA.
Enter the MRC codes of the individual characteristics of the description which are marked proprietary on the technical data, using and coding ($) for multiple characteristics. If all the MRCS are proprietary, enter the reply PACS. If none of the MRCS is proprietary, enter the reply NPAC.
(PRPYAPACS*;PRPYANPAC*; PRPYAMATL$$ASURF*)
CXCY*GPART NAME ASSIGNED BY CONTROLLING AGENCY
THE NAME ASSIGNED TO THE ITEM BY THE GOVERNMENT AGENCY OR COMMERCIAL ORGANIZATION CONTROLLING THE DESIGN OF THE ITEM.
Enter the reply in clear text.
(CXCYGLINE PROCESSOR CONTROL BOARD*)
ZZZK*JSPECIFICATION/STANDARD DATA
THE DOCUMENT DESIGNATOR OF THE SPECIFICATION OR STANDARD WHICH ESTABLISHED THE ITEM OF SUPPLY.
Enter the applicable Reply Code from the table below, followed by the Commercial and Government Entity (CAGE) Code of the entity controlling the document, a dash, and the document designator. The agency that controls the limited coordination document must be preceded and followed by a slash following the designator. The word canceled or superseded must be preceded and followed by a slash for the designator. Professional and industrial association specifications/standards are differentiated from a manufacturer's specification in that the data has been coordinated and published by the professional and industrial association. Include amendments and revisions where applicable.
(ZZZKJT81337-30642B*;ZZZKJS81349-MIL-D-180 REV1/CANCELED/*;ZZZKJP80205-NAS1103*;ZZZKJS81349-MIL-C-1140C/CE/*;ZZZKJT81337-30642B$$JP80205-NAS1103*)
| Table 1 |
| Reply Code (AN62) | Reply |
| V | FEDERAL MOTOR VEHICLE SAFETY STANDARD |
| F | FLAMMABILITY STANDARD |
| S | GOVERNMENT SPECIFICATION |
| T | GOVERNMENT STANDARD |
| U | INTERNATIONAL STD/SPEC |
| D | MANUFACTURERS SOURCE CONTROL |
| R | MANUFACTURERS SPECIFICATION |
| N | MANUFACTURERS SPECIFICATION CONTROL |
| M | MANUFACTURERS STANDARD |
| B | NATIONAL STD/SPEC |
| A | PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
| P | PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
If the specification/standard cited in reply to MRC ZZZK is nondefinitive, reply to MRC ZZZT. This reply is the data which is not recorded in Segment C.
ZZZT*JNONDEFINITIVE SPEC/STD DATA
THE NUMBER, LETTER, OR SYMBOL INDICATING THE TYPE, STYLE, GRADE, CLASS, AND THE LIKE OF AN ITEM IN A NONIDENTIFYING SPECIFICATION OR STANDARD.
Enter the applicable Reply Code from the table below followed by the appropriate number, letter or symbol.
(ZZZTJTY1*; ZZZTJTY1$$JSTA*; ZZZTJTY1$JSTA*)
| Table 1 |
| Reply Code (AD08) | Reply |
| AL | ALLOY |
| BE | ANNEALED |
| AN | ANNEX |
| AP | APPENDIX |
| AC | APPLICABILITY CLASS |
| AR | ARRANGEMENT |
| AS | ASSEMBLY |
| AB | ASSORTMENT |
| BF | BOND |
| BX | BOX |
| CY | CAPACITY |
| CA | CASE |
| CT | CATEGORY |
| CF | CIRCUMFERENCE |
| CL | CLASS |
| CE | CODE |
| CR | COLOR |
| CC | COMBINATION CODE |
| CN | COMPONENT |
| CP | COMPOSITION |
| CM | COMPOUND |
| CD | CONDITION |
| AV | CONFIGURATION |
| CS | CONSTRUCTION |
| BG | CORE CONDITION |
| CB | CUT OFF |
| AM | DELAY CLASS |
| DE | DESIGN |
| DG | DESIGNATOR |
| DW | DRAWING NUMBER |
| DU | DUPLEX |
| EG | EDGE |
| EN | END |
| FY | FAMILY |
| FG | FIGURE |
| AK | FILE NUMBER |
| FN | FINISH |
| FB | FLAVOR |
| BH | FLUX PERCENTAGE |
| FM | FORM |
| FA | FORMULA |
| AJ | GAGE STOCK NUMBER |
| GR | GRADE |
| GA | GRADUATION |
| AX | GRANULES |
| AY | GRIT |
| GB | GROUND |
| GP | GROUP |
| HA | HEAVY DUTY |
| BA | IMAGE COLOR |
| NS | INSERT |
| TM | ITEM |
| KD | KIND |
| KT | KIT |
| LG | LENGTH |
| LV | LEVEL |
| LT | LIMIT |
| MK | MARK |
| AA | MARKER |
| AD | MASK APERTURE |
| ML | MATERIAL |
| BB | MAXIMUM DENSITY |
| TA | MEDIUM TEMPER |
| MH | MESH |
| ME | METHOD |
| BC | MINIMUM DENSITY |
| MD | MODEL |
| MT | MOUNTING |
| AQ | NATURAL |
| AU | NON-DELAY CLASS |
| NR | NUMBER |
| BL | OUTFIT NUMBER |
| PA | PARAGRAPH |
| PT | PART |
| PN | PATTERN |
| PC | PHYSICAL CONDITION |
| PS | PIECE |
| PL | PLAN |
| PR | POINT |
| PD | POLISHED |
| PB | PRESSURE RATING |
| QA | QUALITY |
| QB | QUENCHED |
| RN | RANGE |
| AE | RAPID |
| RT | RATING |
| RF | REFERENCE NUMBER |
| RA | REGULAR DUTY |
| BJ | RMA FLUX |
| SJ | SALIENT CHARACTERISTICS |
| SC | SCHEDULE |
| SB | SECTION |
| SL | SELECTION |
| BD | SERIALIZED |
| SE | SERIES |
| SV | SERVICE |
| SX | SET |
| SA | SHADE |
| SH | SHAPE |
| SG | SHEET |
| SZ | SIZE |
| AG | SLOW |
| TC | SOFT TEMPER |
| SK | SOURCE |
| PZ | SPECIES |
| SQ | SPECIFICATION SHEET |
| SD | SPEED |
| AW | STANDARD |
| SR | STRAIGHT |
| ST | STYLE |
| SS | SUBCLASS |
| SF | SUBFORM |
| SP | SUBTYPE |
| BK | SUPPORT |
| SN | SURFACE CONDITION |
| SY | SYMBOL |
| SM | SYSTEM |
| TB | TABLE |
| TN | TANNAGE |
| TP | TEMPER |
| TX | TEXTURE |
| TK | THICKNESS |
| TT | TREATMENT |
| TR | TRIM |
| TY | TYPE |
| YN | UNIT |
| AZ | UNSERIALIZED |
| VA | VARIETY |
| WT | WEIGHT |
| WD | WIDTH |
ZZZY*GREFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS
A FEATURE OF THE ITEM OF SUPPLY WHICH MUST BE SPECIFICALLY RECORDED WHEN THE REFERENCE NUMBER COVERS A RANGE OF ITEMS.
Enter the reply in clear text.
(ZZZYGCOLOR CODED LEADS*; ZZZYGAS DIFFERENTIATED BY MATERIAL*)
APPAJOUTPUT VOLTAGE RATING
THE OUTPUT VALUE/S/,OR RANGE OF VALUES,FOR WHICH THE ITEM IS RATED.
Enter the applicable Reply Code from Tables 1 & 2 & 3 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(APPAJBVB2.0*;APPAJBVB2.0$$JBVB2.1*)
| Table 1 |
| Reply Code (AB62) | Reply |
| B | AC |
| C | DC |
| Table 2 |
| Reply Code (AB63) | Reply |
| K | KILOVOLTS |
| M | MEGAVOLTS |
| U | MICROVOLTS |
| L | MILLIVOLTS |
| V | VOLTS |
| Table 3 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CLQL*GCOLLOQUIAL NAME
A COMMON USAGE NAME BY WHICH AN ITEM IS KNOWN.
Enter the reply in clear text.
(CLQLGWOVEN WIRE CLOTH*)